Browse all practice questions for the FDNY COF for Fire Alarm Systems Inspection, Testing and Service Technician (S-98) Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

FDNY COF for Fire Alarm Systems Inspection, Testing and Service Technician (S-98) Practice Exam 2026 - Free Fire Alarm Systems Technician Practice Questions and Study Guide course image
All questions

These questions are part of the practice quiz. Start practicing

  • Which statement correctly describes the three locations that may be used to recall elevators for firefighter service recall?
  • If a monitored conductor experiences a single open or ground fault, what indication is expected?
  • What is the purpose of an addressable fire alarm device?
  • For elevator recall in firefighter service, which three detector locations are used to recall elevators, unless the AHJ requires otherwise?
  • An impairment coordinator is:
  • Name two common fire detector types used to detect smoke.
  • Which document confirms acceptance testing by the FDNY in NYC after a system is installed?
  • Visible signaling appliances installed in corridors less than 20 feet long must be installed within what distance of the end of the corridor, with what maximum separation between appliances?
  • What describes a circuit where signals from multiple devices are transmitted without identifying the activated device?
  • When installing heat detectors on ceilings, a row detector should be located within how many feet of the ceiling peak?
  • In NYC, which document confirms the fire alarm system has passed acceptance testing by the FDNY?
  • A bean is defined as a structural member that could drop into the room’s base more than how many inches and be located more than how many feet apart on center?
  • What is the role of an addressable fire alarm device?
  • Explain the difference between Initiating Device Circuits (IDC) and Notification Appliance Circuits (NAC).
  • During an inspection, which item helps maintain traceability for uninstalled devices?
  • What information should be included on a fire alarm system test tag or report?
  • If a fault is recorded in the trouble memory, what is the recommended action?
  • The ongoing maintenance obligation for fire and life safety systems is assigned to which party?
  • Which of the following are initiating devices?
  • Which statement best describes the two common smoke detector types?
  • All of the following are good conductors of electricity except which material?
  • What is the purpose of maintaining a detailed service log for a fire alarm system?
  • Which test validates that a newly installed or modified fire alarm system meets code and is acceptable to the AHJ?
  • Travel distance to the nearest fire alarm box shall not exceed how many feet?
  • What is the purpose of tagging an uninstalled device during inspection?
  • Who may require deviation from the standard locations for elevator recall detectors, if applicable?
  • What is the maximum distance allowed for a shunt loop circuit?
  • Which detector type is typically more sensitive to slow, smoldering fires?
  • Which statement best describes the proper handling of unused devices until installation or removal?
  • If heat detectors shut down elevator power prior to sprinkler operation, the detector shall be placed within how many feet of each sprinkler head?
  • What does sensitivity testing of smoke detectors ensure?
  • Complete records of all signals received at a supervising station must be retained for at least how long?
  • Which labeling requirement is also required for Autubel devices besides sound pressure level?
  • What is a functional test and what should it verify in a fire alarm system?
  • Which type of document is included among the required information to be provided on site?
  • What is central station monitoring?
  • What is the primary purpose of the smoke detector maintenance log?
  • In the typical sequence of operation when a smoke detector is triggered in an automatic fire alarm system, what is the first action?
  • What type of detector is primarily used for fast detection of flaming fires?
  • A listed relay used to initiate fire safety functions shall be located within how many feet of the controlled circuit or appliance?
  • For visible signaling appliances, the flash rate shall not exceed and shall not be less than what values across the listed voltage range?
  • If you fail the written test you will not be permitted to retest for how many days?
  • The owner is primarily responsible for what aspect of fire and life safety systems?
  • A S98 certificate of fitness holder may perform all the following functions except:
  • What is a Class B circuit in fire alarm wiring?
  • What is the maximum candela (cd) rating allowed for a visible signaling appliance?
  • What is an elevator recall and when is it used?
  • Which statement accurately reflects the location requirement for essential documents?
  • Which statement about the trouble memory is false?
  • Wall mounting of visible signaling appliances must place the lens within what height range above the finished floor?
  • What type of permit is typically required to perform any work on a fire alarm system in NYC?
  • Which option is NOT part of the recommended handling of unused devices?
  • In ceiling detector layouts, heat detectors should be placed so that row detectors are within how many feet of the peak?
  • During inspection, how should uninstalled or unused devices be handled?
  • Which circuit provides power to audible/visual notification appliances?
  • Public mode audible devices shall have a sound level at least how many decibels above the average ambient sound level, or above the maximum sound level for 60 seconds, whichever is greater?
  • The phrase 'as built design and installation documents and equipment specifications' refers to which type of content?
  • In the same room scenario, how many visible appliances are required?
  • What is the purpose of a permit-to-test in NYC and why is it required?
  • According to NFPA 72 Chapter 9, where must the shunt circuit conductors of auxiliary fire alarm systems be installed?
  • When is the NFPA 72 record of completion prepared?
  • How should a technician document a system modification or addition to the fire alarm system?
  • What two actions must a digital alarm communicator transmitter perform?
  • What is the purpose of testing the response of notification appliances during a functional test?
  • What component is used to test water flow devices by allowing water to flow during testing?
  • NFPA 72 requires manual fire alarm boxes to be conspicuous, unobstructed, and ________.
  • Who is responsible for making entries in the smoke detector maintenance log if no Fire Safety Director is appointed, according to fire rules?
  • Why is it important to maintain records indicating the status of unused devices?
  • Who is responsible for reporting an out-of-service fire protection system to the fire department and when must it be reported?
  • Which of the following is NOT a typical sign that a fire alarm battery is failed and needs replacement?
  • What is one of the name plate requirements for audible appliances?
  • What does a Signaling Line Circuit (SLC) do in addressable fire alarm systems?
  • Which action is described as incorrect for control station handling of an alarm signal?
  • Name the three types of signals created by a fire alarm system.
  • Which statement is NOT a qualification for the S98 certificate of fitness?
  • Which drawing is specifically used to convey the vertical distribution of circuits and conductor counts across floors?
  • Why is a 'trouble' signal important in fire alarm supervision?
  • Ionization smoke detectors are examples of which type of detection in this context?
  • What is the minimum distance, in feet, from an air diffuser for a spot-type smoke detector?
  • Which statement about remote supervising station staffing is correct?
  • Which statement best describes the function of the trouble memory in a fire alarm panel?
  • What is the recommended wording in records to reflect the status of an uninstalled device?
  • Which device labeling requirement is specifically associated with Autubel devices?
  • Which authority has the stated role in approving pre-signal system installations?
  • Why is it important to avoid disturbing a system that is in alarm or being reset without proper authority or procedure?
  • Which person is charged with ensuring proper safety precautions when a fire protection system is out of service?
  • What is an acceptance test?
  • The time period before you may retake the written exam after a failure is 90 days.
  • Why is coordination with the building's life safety team important during testing?
  • What unit of measurement is used to express the output rating of visible signaling devices?
  • Which documents are included as part of the required information to be provided?
  • When reporting uninstalled devices, what should be included in the records?
  • If multiple visible signaling appliances are in the same field of view, how must they operate relative to one another?
  • Fire pumps shall be supervised for which supervisory signal?
  • The term 'Stooped' describes which type of ceiling?
  • Which standard forms the basis for fire alarm system design, installation, testing, and maintenance referenced by the FDNY S-98 exam?
  • What are the three main subsystems of a typical fire alarm system?
  • Which of the following is an example of an initiating device?
  • Where is an annunciator panel typically located in a fire alarm system?
  • Under NFPA chapter 4, which information must be permanently marked on batteries?
  • What type of tests are commonly performed to verify the functionality of all initiating devices?
  • What is the role of a notification appliance in a fire alarm system?
  • Is a digital alarm communicator transmitter serving an office building, owned by the building owner and connected to tenant-owned telephone lines, compliant with NFPA 72?
  • In NYC, what is the purpose of documenting test results with a next due date on each device?
  • What does FACP stand for in typical fire alarm systems?
  • Where shall inspection, testing, and maintenance instructions and related documents be provided?
  • What type of drawing typically shows correct conductor counts?
  • The occurrence of a single open or single ground fault condition in installation conductors must be automatically indicated within how many seconds?
  • In a Class B circuit, what happens if a fault occurs?
  • How many water flow switches are allowed on a single IDC?
  • NFPA 72 sets a maximum travel distance to the nearest fire alarm box from any point as which of the following?
  • When heat detectors are used to shut down elevator power prior to sprinkler operation, the detector shall have both a ________ ________ ___________ and a __________ _____________ as compared to the sprinkler.
  • Who is typically the AHJ for fire alarm permits in NYC?
  • What information should technicians record on a test tag or report for each device tested?
  • An initiating device that is destroyed as a result of its operation is what type?
  • After a trouble condition is cleared, what is the recommended step before signaling or testing again?
  • During the sequence of operation, what is activated after the initiating device signals the control panel?
  • What is the importance of maintaining a clean test environment and not contaminating detectors during testing?
  • Which wiring methods are permitted for shunt circuit conductors of auxiliary fire alarm systems?
  • Which of the following is a primary purpose of the trouble memory?
  • To assure proper calibration, which method is NOT permitted for testing a smoke detector?
  • If a digital alarm communicator transmitter calls a number that is forwarded to the receiver, how often must the integrity of the call forwarding be verified?
  • The time from off-hook to on-hook per attempt for a digital alarm communicator transmitter must not exceed how many seconds?
  • What does 'supervision' mean in fire alarm circuits?
  • Which component processes signals from initiating devices and coordinates alarm responses?
  • If maintenance documents need to be accessed readily during work, where should they be located?
  • In combined fire protection systems, what is the function of a water flow switch?
  • Secondary power supplies for emergency voice evacuation systems must operate in a non-alarm condition for how many hours and, under maximum load, for a minimum of how many minutes?
  • What is the purpose of including a 'next due date' on a fire alarm test tag or report?
  • What is the minimum interval for automatic test transmissions by a digital alarm communicator transmitter?
  • Secondary power supply shall automatically provide power to the protected premises fire alarm system within how many seconds when primary power fails?
  • What does SLC stand for in addressable fire alarm systems?
  • What is the difference between 'quarterly test' and 'annual test' in routine inspection schedules?
  • What is the function of the Fire Alarm Control Panel (FACP)?
  • What is the primary purpose of a heat detector in a fire alarm system?
  • Which candela rating would be used for a visible alarm appliance in a 20' × 20' room?
  • Which of the following statements about the trouble memory is false?
  • Pre-signal systems may be installed under which condition?
  • Which candela reading and how many visible appliances are required for a visible alarm in a 20' × 20' room?
  • How should water flow devices be tested?
  • Within how many hours after batteries have been fully discharged should the control panel charging apparatus be recharged?
  • Building evacuation signals must meet the ANSI 53.41 Temporal 3 signal for which type of system notification?
  • Remote supervising stations are required to be manned at all times; what is the minimum number of trained persons on duty?
  • Which option would be a compliant approach for pre-signal system installations?
  • Before stepping away from a system in trouble condition, what is the recommended practice?
  • What is the maximum number of water flow switches permitted on a single IDC?
  • What is the smallest conductor size allowed for shunt type circuits?
  • Where should a listed relay that initiates fire safety functions be located in relation to the controlled circuit?
  • A coded alarm signal shall consist of not less than how many rounds, and each round shall have not less than how many impulses?
  • Which statement best describes the goal of a functional test in a fire alarm system?
  • Pre-signal system installations require approval from which official?
  • When a modification or addition is made to a fire alarm system, which action is essential to maintain regulatory compliance?
  • A digital alarm communicator transmitter shall automatically initiate and complete a test signal transmission to its associated receiver at least once every how many hours?
  • What is the purpose of the 'trouble' memory in a fire alarm control panel?
  • Who is responsible for making entries in the smoke detector maintenance log if there is no Fire Safety Director?
  • Which statement best reflects the required minimum hours for non-alarm operation of a standard fire alarm secondary power supply?
  • What is a Class A circuit in fire alarm wiring?
  • What is the minimum distance for mounting a spot-type smoke detector from an air supply diffuser?
  • Secondary power supplies are required to have sufficient power to operate the fire alarm system in a non alarm condition for how many hours and then be capable of operating all notification devices for a minimum of how many minutes?
  • Who is responsible for ensuring fire and life safety systems are maintained in good working order at all times?
  • Which statement about permit-to-test is true?
  • Which device is used to manually initiate a fire alarm?
  • According to NFPA chapter 4, batteries shall be permanently marked with which information?
  • Records of inspections, testing, servicing, or maintenance must be retained on site for how long?
  • Which of the following is NOT an example of line-type detection?
  • How should you approach a fire alarm system that is in trouble condition before performing further work?
  • Which statement accurately lists the three signals produced by a fire alarm system?
  • What is the purpose of labeling and identifying devices during inspection?
  • During a field inspection, a fault is recorded in the trouble memory. What is the appropriate action?
  • Under the New York City Fire Code, which testing method is not permitted for smoke detectors?
  • A signaling line circuit is a circuit to which automatic or manual initiating devices are connected where the signal received does what?
  • When testing for proper calibration of smoke detectors, which option would be disallowed?
  • According to fire code and fire rules, who is responsible for preventing unnecessary and unwanted alarms?
  • According to section 901.6.2, records of system inspections, testing, servicing or other maintenance must be maintained on the premise for a period of years?
  • Upon receipt of a trouble signal, within how many hours must maintenance personnel arrive to initiate service?
  • Based on FC802 definitions, which is not a cause of an unwarranted alarm?
  • A digital alarm communicator transmitter shall be connected to how many separate means of transmission at the protected premises?
  • Which metal is commonly used as a reliable electrical conductor in wiring?
  • What is an annunciator in a fire alarm system?
  • Electrical equipment must be capable of operating at what percentage of its nameplate voltage?